Yamaha PW error codes
All 23 Yamaha PW codes we have documented: what each one means, what stops working and what you can do yourself before going to a dealer. Applies to PW series, PW-X2/X3, PW-S2 drive units.
Numeric error code on the display unit ('The display indicates an error code'); some displays show text such as 'SPD SNSR / CHK MAGNET'. Battery capacity LEDs flashing (alternately/simultaneously) indicate battery or charger faults.
Get Yamaha news & firmware updates in Telegram| Code | Meaning | What to do |
|---|---|---|
| 12 | Display unit: communication with the display has stopped. Clears by itself once the fault is gone. | Check the display connector. If it persists, the dealer replaces the display, its cable or the drive unit electronics. |
| 13 | Drive unit and display: corrupted data sent to the display, often an incompatible pairing. | Check that the drive unit and display are a compatible combination (dealer). |
| 31 | Torque sensor: no signal, disconnected or short circuit in the wiring to the controller. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the torque sensor, or the controller board / drive unit. |
| 32 | Torque sensor: poor connection between coil and circuit board (wire almost broken). Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the torque sensor, or the controller board / drive unit. |
| 33 | Torque sensor: abnormal no-load voltage. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. | Dealer job: run the torque sensor reference voltage adjustment; otherwise replace the torque sensor or the controller board / drive unit. |
| 34, 35, 36, 37 | Torque sensor: abnormal voltage while riding (high constant voltage, at low speed or other cases). Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. | Dealer job: torque sensor reference voltage adjustment, then torque sensor or controller replacement if needed. |
| 38 | Crank sensor: abnormal U-phase current sensor voltage while the motor is idle. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the torque sensor, the controller or the drive axle. |
| 39 | Crank sensor: abnormal W-phase current sensor voltage while the motor is idle. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the controller board or the drive unit. |
| 61 | Controller: overcurrent on a motor phase (U, V or W). Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the controller board or the drive unit. |
| 62 | Motor: abnormal current on a motor phase. Does not clear with a restart. | Dealer job: replace the controller board or the drive unit. |
| 63 | Controller: data read failure. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the controller board or the drive unit. |
| 64 | Controller: circuit board temperature out of range (below about -20 °C or above about 125 °C) or a board sensor is coming loose. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. | Let the bike reach a normal temperature and restart. If it persists, the dealer replaces the controller board or the drive unit. |
| 66 | Controller: external memory (EEPROM) data error. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the controller board or the drive unit. |
| 67 | Motor: one or more motor phase wires disconnected (yellow U, blue V or white W). Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the controller board / drive unit or the motor wire leads. |
| 68 | Encoder: wire disconnected or short-circuited. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: check the encoder connector and lead; otherwise replace the controller or the motor. |
| 71 | Battery: data from the battery can't be read. Usually clears after switching the system off and on, if the fault is gone. | Check the contacts between battery and bike and the charging port. If it persists, the dealer checks the DC socket, wiring, controller or battery. |
| 73 | Battery: voltage too high (about 45 V detected). Usually clears after switching the system off and on, if the fault is gone. | Dealer job: check connections and wiring; replace the controller or battery if needed. |
| 74 | Battery: internal system failure; the charge indicator may flash abnormally. | Dealer job: battery service according to Yamaha's battery service manual. |
| 79 | DC/DC converter: abnormal DC current. Usually clears after switching the system off and on, if the fault is gone. | Dealer job: replace the external DC/DC converter or the controller board / drive unit. |
| Speed sensor (no number) | Speed sensor disconnected; no speed shown while riding. Clears by itself once the fault is gone. | Check the speed sensor connector and the gap between sensor and spoke magnet (Yamaha specifies 5-17 mm). Replace the sensor set if needed. |
- Many Yamaha errors clear when power is cycled; if the same error recurs it may not clear and needs a dealer.
- Both battery capacity LEDs flashing simultaneously = battery protection activated; have the battery replaced at a dealer.
Written in our own words from the manufacturer’s documentation. Codes can change with firmware; your dealer’s diagnostic software has the final word. Sources: cdn2.yamaha-motor.eu
FAQ
What does Yamaha 34, mean?
Torque sensor: abnormal voltage while riding (high constant voltage, at low speed or other cases). Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. What to do: Dealer job: torque sensor reference voltage adjustment, then torque sensor or controller replacement if needed.
What does Yamaha 64 mean?
Controller: circuit board temperature out of range (below about -20 °C or above about 125 °C) or a board sensor is coming loose. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. What to do: Let the bike reach a normal temperature and restart. If it persists, the dealer replaces the controller board or the drive unit.
How do I avoid Yamaha error codes?
Many Yamaha errors clear when power is cycled; if the same error recurs it may not clear and needs a dealer. Both battery capacity LEDs flashing simultaneously = battery protection activated; have the battery replaced at a dealer.
Motors: Yamaha PW-X3. Yamaha firmware updates. Other systems: Bosch Smart System, Bosch classic (Gen 2 to 4), Shimano STEPS / EP, DJI Avinox, TQ HPR, Fazua Ride 60, Specialized Turbo, Giant SyncDrive.