Error codes · Yamaha

Yamaha PW error codes

All 23 Yamaha PW codes we have documented: what each one means, what stops working and what you can do yourself before going to a dealer. Applies to PW series, PW-X2/X3, PW-S2 drive units.

Numeric error code on the display unit ('The display indicates an error code'); some displays show text such as 'SPD SNSR / CHK MAGNET'. Battery capacity LEDs flashing (alternately/simultaneously) indicate battery or charger faults.

Get Yamaha news & firmware updates in Telegram
CodeMeaningWhat to do
12Display unit: communication with the display has stopped. Clears by itself once the fault is gone.Check the display connector. If it persists, the dealer replaces the display, its cable or the drive unit electronics.
13Drive unit and display: corrupted data sent to the display, often an incompatible pairing.Check that the drive unit and display are a compatible combination (dealer).
31Torque sensor: no signal, disconnected or short circuit in the wiring to the controller. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the torque sensor, or the controller board / drive unit.
32Torque sensor: poor connection between coil and circuit board (wire almost broken). Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the torque sensor, or the controller board / drive unit.
33Torque sensor: abnormal no-load voltage. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing.Dealer job: run the torque sensor reference voltage adjustment; otherwise replace the torque sensor or the controller board / drive unit.
34, 35, 36, 37Torque sensor: abnormal voltage while riding (high constant voltage, at low speed or other cases). Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing.Dealer job: torque sensor reference voltage adjustment, then torque sensor or controller replacement if needed.
38Crank sensor: abnormal U-phase current sensor voltage while the motor is idle. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the torque sensor, the controller or the drive axle.
39Crank sensor: abnormal W-phase current sensor voltage while the motor is idle. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the controller board or the drive unit.
61Controller: overcurrent on a motor phase (U, V or W). Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the controller board or the drive unit.
62Motor: abnormal current on a motor phase. Does not clear with a restart.Dealer job: replace the controller board or the drive unit.
63Controller: data read failure. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the controller board or the drive unit.
64Controller: circuit board temperature out of range (below about -20 °C or above about 125 °C) or a board sensor is coming loose. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing.Let the bike reach a normal temperature and restart. If it persists, the dealer replaces the controller board or the drive unit.
66Controller: external memory (EEPROM) data error. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the controller board or the drive unit.
67Motor: one or more motor phase wires disconnected (yellow U, blue V or white W). Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the controller board / drive unit or the motor wire leads.
68Encoder: wire disconnected or short-circuited. Usually clears after switching the system off and on, if the fault is gone.Dealer job: check the encoder connector and lead; otherwise replace the controller or the motor.
71Battery: data from the battery can't be read. Usually clears after switching the system off and on, if the fault is gone.Check the contacts between battery and bike and the charging port. If it persists, the dealer checks the DC socket, wiring, controller or battery.
73Battery: voltage too high (about 45 V detected). Usually clears after switching the system off and on, if the fault is gone.Dealer job: check connections and wiring; replace the controller or battery if needed.
74Battery: internal system failure; the charge indicator may flash abnormally.Dealer job: battery service according to Yamaha's battery service manual.
79DC/DC converter: abnormal DC current. Usually clears after switching the system off and on, if the fault is gone.Dealer job: replace the external DC/DC converter or the controller board / drive unit.
Speed sensor (no number)Speed sensor disconnected; no speed shown while riding. Clears by itself once the fault is gone.Check the speed sensor connector and the gap between sensor and spoke magnet (Yamaha specifies 5-17 mm). Replace the sensor set if needed.
  • Many Yamaha errors clear when power is cycled; if the same error recurs it may not clear and needs a dealer.
  • Both battery capacity LEDs flashing simultaneously = battery protection activated; have the battery replaced at a dealer.

Written in our own words from the manufacturer’s documentation. Codes can change with firmware; your dealer’s diagnostic software has the final word. Sources: cdn2.yamaha-motor.eu

FAQ

What does Yamaha 34, mean?

Torque sensor: abnormal voltage while riding (high constant voltage, at low speed or other cases). Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. What to do: Dealer job: torque sensor reference voltage adjustment, then torque sensor or controller replacement if needed.

What does Yamaha 64 mean?

Controller: circuit board temperature out of range (below about -20 °C or above about 125 °C) or a board sensor is coming loose. Usually clears after a restart; if it keeps returning, it no longer clears and the part needs replacing. What to do: Let the bike reach a normal temperature and restart. If it persists, the dealer replaces the controller board or the drive unit.

How do I avoid Yamaha error codes?

Many Yamaha errors clear when power is cycled; if the same error recurs it may not clear and needs a dealer. Both battery capacity LEDs flashing simultaneously = battery protection activated; have the battery replaced at a dealer.

Motors: Yamaha PW-X3. Yamaha firmware updates. Other systems: Bosch Smart System, Bosch classic (Gen 2 to 4), Shimano STEPS / EP, DJI Avinox, TQ HPR, Fazua Ride 60, Specialized Turbo, Giant SyncDrive.