Error codes · TQ

TQ HPR error codes

All 280 TQ HPR codes we have documented: what each one means, what stops working and what you can do yourself before going to a dealer. Applies to also HPR40/HPR60 systems.

Code on the top-tube display as 'ERR'/'WRN' + 4-character hex code + component label (DRV = drive unit, BATT = battery, SPD SENS = speed sensor, DISP = display). Since the July 2025 app update, error codes are also shown in the TQ E-Bike app.

Get TQ news & firmware updates in Telegram

Error codes (74)

CodeMeaningWhat to do
ERR 0401, 040B, 040C, 040D, 040E, 040F, 042B, 042E, 0479, 047A, 047B, 04A7, 04A9, 04AA, 04C8, 04C9, 04CA, 04CBDrive unit: general software error (DRV SW).Restart the system. If the error comes back, see a TQ dealer.
ERR 0403, 0498, 0499, 049ADrive unit: communication error with a connected component (DRV COMM).Restart the system. If the error comes back, see a TQ dealer.
ERR 0405Walk assist communication error (DISP COMM).Restart the system. If the error comes back, see a TQ dealer.
ERR 0407, 0440Drive unit electronics error.Restart the system. If the error comes back, see a TQ dealer.
ERR 0408, 0445, 047DDrive unit overcurrent.Restart the system and avoid misuse (for example overloading the motor). If the error comes back, see a TQ dealer.
ERR 0415Drive unit configuration error.Dealer job: see a TQ dealer.
ERR 0416General software error on the battery link (BATT COMM).Restart the system. If the error comes back, see a TQ dealer.
ERR 0418The display failed to initialise (DISP COMM).Restart the system. If the error comes back, see a TQ dealer.
ERR 041DDrive unit memory error (DRV HW or DRV SW).Restart the system. If the error comes back, see a TQ dealer.
ERR 0451, 0452, 047FDrive unit too hot or too cold (DRV HOT).The motor is outside its permitted temperature range. Switch off, let it cool down (or warm up), then restart. If the error comes back, see a TQ dealer.
ERR 0453The drive unit failed to initialise.Restart the system. If the error comes back, see a TQ dealer.
ERR 0457Drive unit voltage error (BATT CONN).Restart the system. If the error comes back, see a TQ dealer.
ERR 0458Drive unit overvoltage, usually from the charger (BATT CONN).Use only the original TQ charger; replace it if it's faulty. If the error comes back, see a TQ dealer.
ERR 045D, 0469General or critical battery error (BATT GEN).Restart the system. If the error comes back, see a TQ dealer.
ERR 0465, 0475, 0481, 04A6Battery communication error: timeout, failed initialisation or lost link (BATT COMM).Restart the system. If the error comes back, see a TQ dealer.
ERR 0477, 0482Drive unit software configuration is incorrect.Restart the system. If the error comes back, see a TQ dealer.
ERR 0480Drive unit assist error (DRV SENS).Restart the system and avoid misuse (for example overloading the motor). If the error comes back, see a TQ dealer.
ERR 0483, 0484, 0485, 0486, 0487, 0488, 0489, 048A, 048B, 048C, 048D, 048E, 048F, 0490, 0491, 0492Drive unit software runtime error.Restart the system. If the error comes back, see a TQ dealer.
ERR 0493, 0495Drive unit voltage error.Restart the system. If the error comes back, see a TQ dealer.
ERR 0494Supply voltage problem.Restart the system. If the error comes back, see a TQ dealer.
ERR 0496Broken motor phase in the drive unit.Restart the system. If the error comes back, see a TQ dealer.
ERR 0497Drive unit calibration error.Restart the system. If the error comes back, see a TQ dealer.
ERR 049B, 04A3, 04A4Cadence sensor error.Restart the system. If the error comes back, see a TQ dealer.
ERR 049C, 049D, 049E, 049F, 04A5Torque sensor error.Restart the system and avoid misuse (for example overloading the motor). If the error comes back, see a TQ dealer.
ERR 04A0, 04A1CAN bus communication error.Check the charging port for dirt, then restart. If the error comes back, see a TQ dealer.
ERR 04A2Microcontroller electronics error.Restart the system. If the error comes back, see a TQ dealer.
ERR 04A8Speed sensor error (SPD SENS).Check the gap between the speed sensor and the magnet, and that nothing has been tampered with. If the error comes back, see a TQ dealer.
ERR 04AE, 04AFCadence sensor error (DRV SW).Restart the system. If the error comes back, see a TQ dealer.
ERR 04ADDrive unit control error.Restart the system. If the error comes back, see a TQ dealer.
ERR 04B0Mechanical problem in the drive unit.Check whether something is jammed or wedged in the chainring. If the error comes back, see a TQ dealer.
ERR 4401, 4403, 4405, 4418, 4419, 4424, 4428, 4429, 442A, 442B, 442C, 4430, 4431, 4432, 4433, 4434, 4435, 4437, 4439, 443D, 443F, 4441, 4442, 4443, 4444, 4446, 4447, 4448, 444B, 4455, 4462, 4463, 446C, 446E, 4471, 4472, 4473, 447B, 447C, 4486, 448A, 448B, 448F, 4490, 4495, 4496Battery hardware failure (BATT HW).Restart the system. If the error comes back, see a TQ dealer.
ERR 4476, 447F, 4483, 4484, 448E, 449A, 449BBattery fault (BATT GEN).Restart the system. If the error comes back, see a TQ dealer.
ERR 4404, 4449Battery CAN initialisation not possible / battery software error.Restart the system. If the error comes back, see a TQ dealer.
ERR 4407, 4408, 4450, 4492Battery cell voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 440C, 4412Battery voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 4409Battery deeply discharged or a cell is defective.Charge the battery immediately, then restart. If the error comes back, see a TQ dealer.
ERR 440ABattery voltage too low.Charge the battery immediately. If the error comes back, see a TQ dealer.
ERR 440EBattery short circuit.Restart the system. If the error comes back, see a TQ dealer.
ERR 440F, 4411Battery voltage too low, often because the battery is too cold or hot.Let the battery cool down or warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 4410Voltage difference between battery cells too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 4414Measured cell voltage difference too high.Restart and make sure the battery runs firmware 1.99.5 or newer. If the error comes back, see a TQ dealer.
ERR 4415, 4417Battery or cell voltage too low.Restart the system. If the error comes back, see a TQ dealer.
ERR 4416The battery can't be charged.Restart the system. If the error comes back, see a TQ dealer.
ERR 441B, 4494Temperature difference between battery cells too high.Let the battery cool down or warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 441C, 441E, 4420, 4421, 4491, 442F, 4474, 4475Battery (cell) temperature too high (BATT HOT).Let the battery cool to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 441D, 441F, 4422, 4423Battery cell temperature too low (BATT COLD).Let the battery warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 442D, 4436Battery hardware failure, possibly at the connector.Restart and check that the battery connector is fully plugged in and clean. If the error comes back, see a TQ dealer.
ERR 443A, 443B, 443EBattery overcurrent while charging or discharging.Restart the system. If the error comes back, see a TQ dealer.
ERR 4464Battery reference voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 4485Battery software doesn't match the Range Extender.Try riding without the Range Extender, then restart. If the error comes back, see a TQ dealer.
ERR 4487Battery or Range Extender software is out of date.Dealer job: the battery or Range Extender software has to be updated with TQ's service tool (DST).
ERR 5001, 5003, 5005, 5018, 5019, 5024, 5028, 5029, 502A, 502B, 502C, 5030, 5031, 5032, 5033, 5034, 5035, 5037, 5039, 503D, 503F, 5041, 5042, 5043, 5044, 5046, 5047, 5048, 504B, 5055, 5062, 5063, 506C, 506E, 5071, 5072, 5073, 507B, 507C, 508A, 508B, 508F, 5090, 5095, 5096Range Extender hardware failure (REX HW).Restart the system. If the error comes back, see a TQ dealer.
ERR 5076, 507F, 5083, 5084, 5086, 508E, 509A, 509BRange Extender fault (REX GEN).Restart the system. If the error comes back, see a TQ dealer.
ERR 5004, 5049Range Extender CAN initialisation not possible / software error.Restart the system. If the error comes back, see a TQ dealer.
ERR 5007, 5008, 5050, 5092Range Extender cell voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 500C, 5012Range Extender voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 5009Range Extender deeply discharged or a cell is defective.Charge the Range Extender immediately, then restart. If the error comes back, see a TQ dealer.
ERR 500ARange Extender voltage too low.Charge the Range Extender immediately. If the error comes back, see a TQ dealer.
ERR 500ERange Extender short circuit.Restart the system. If the error comes back, see a TQ dealer.
ERR 500F, 5011Range Extender voltage too low, often because it is too cold or hot.Let the Range Extender cool down or warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 5010Voltage difference between Range Extender cells too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 5014Measured Range Extender cell difference too high.Restart and make sure the Range Extender runs firmware 1.99.5 or newer. If the error comes back, see a TQ dealer.
ERR 5015, 5017Range Extender or cell voltage too low.Restart the system. If the error comes back, see a TQ dealer.
ERR 5016The Range Extender can't be charged.Restart the system. If the error comes back, see a TQ dealer.
ERR 501B, 5094Temperature difference inside the Range Extender too high.Let the Range Extender cool down or warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 501C, 501E, 5020, 5021, 5091, 502F, 5074, 5075Range Extender (cell) temperature too high.Let the Range Extender cool to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 501D, 501F, 5022, 5023Range Extender cell temperature too low.Let the Range Extender warm up to room temperature, then restart. If the error comes back, see a TQ dealer.
ERR 502D, 5036Range Extender hardware error, possibly the cable.Restart and check the Range Extender cable is plugged in properly and clean; if needed ride without it. If the error comes back, see a TQ dealer.
ERR 503A, 503B, 503ERange Extender overcurrent while charging or discharging.Restart the system. If the error comes back, see a TQ dealer.
ERR 5064Range Extender reference voltage too high.Restart the system. If the error comes back, see a TQ dealer.
ERR 5085Range Extender software doesn't match the battery.If possible try the system without the Range Extender combination that triggers it, then restart. If the error comes back, see a TQ dealer.
ERR 5087Battery or Range Extender software is out of date.Dealer job: the battery or Range Extender software has to be updated with TQ's service tool (DST).
ERR 5401Communication error between drive unit and display (DRV CONN).Restart the system. If the error comes back, see a TQ dealer.
ERR 5402, 5403A remote button was pressed while switching on (DISP BTN).Don't touch the remote buttons during start-up; check for buttons stuck with dirt and clean them.

Warning codes (6)

CodeMeaningWhat to do
WRN 04ABCadence sensor warning.Restart the system. If the error comes back, see a TQ dealer.
WRN 0601, 0605Speed sensor problem: magnet too far from the sensor.Set the magnet to the permitted distance from the speed sensor, then restart. If the error comes back, see a TQ dealer.
WRN 0602Drive unit overheating.Switch off and let the motor cool down, then restart. If the error comes back, see a TQ dealer.
WRN 0603CAN bus communication problem.Check the charging port for dirt, then restart. If the error comes back, see a TQ dealer.
WRN 0604The torque sensor encoder is updating.Wait about a minute and don't switch off so the update can finish. If the error comes back, see a TQ dealer.
WRN 5404Walk assist used incorrectly (DISP BTN).Hold the UP (Walk) button until Walk shows on the display, release it, then press it again to walk. If the error comes back, see a TQ dealer.
  • Most TQ codes: restart; if it recurs, contact a TQ dealer.
  • CAN-bus codes often come from a dirty charging port - clean and dry it.
  • Speed-sensor codes: check magnet distance first.

Written in our own words from the manufacturer’s documentation. Codes can change with firmware; your dealer’s diagnostic software has the final word. Sources: tq-ebike.com · tq-ebike.com

FAQ

What is the difference between TQ E and W codes?

Codes starting with W are warnings: the bike usually keeps working with reduced assist or a limited function, and many clear by themselves. E codes are errors: assist usually stops until the cause is fixed, often with a restart, sometimes only by a dealer.

What does TQ ERR mean?

Speed sensor error (SPD SENS). What to do: Check the gap between the speed sensor and the magnet, and that nothing has been tampered with. If the error comes back, see a TQ dealer.

What does TQ ERR mean?

Drive unit too hot or too cold (DRV HOT). What to do: The motor is outside its permitted temperature range. Switch off, let it cool down (or warm up), then restart. If the error comes back, see a TQ dealer.

How do I avoid TQ error codes?

Most TQ codes: restart; if it recurs, contact a TQ dealer. CAN-bus codes often come from a dirty charging port - clean and dry it. Speed-sensor codes: check magnet distance first.

Motors: TQ HPR50 / HPR60. TQ firmware updates. Other systems: Bosch Smart System, Bosch classic (Gen 2 to 4), Shimano STEPS / EP, DJI Avinox, Fazua Ride 60, Specialized Turbo, Yamaha PW, Giant SyncDrive.